My upstairs unit quit cooling and they were able to come out and get it running. I greatly appreciate you being able to get me on the schedule, you have a customer for life.
SmyrnaGA30082 33.845-84.57John listened to all the concerns we had and walked us through our options
SmyrnaGA30082 33.8575-84.5475SmyrnaGA30080 33.8425-84.4825
Very solid experience owner came out to fix the air con himself over the weekend. No upsell, straightforward and efficient work. Will use again.
SmyrnaGA30082 33.8475-84.575Comfort Solutions did a great job servicing my air conditioning system to get it ready for the summer season. They were thorough, professional, and pleasant to work with.
SmyrnaGA30082 33.87-84.535Prompt, affordable and solid!
SmyrnaGA30082 33.8725-84.535Performed one maintenance on air handler in the basement changed 16 x 20 by one filter checked all electrical components for broken and loose connections checked amperage on fan motor check the voltage on his strips everything is running normal at this time
Performed maintenance on one furnace and one air handler Customer has his own filters Air handler in the attic: changed 16 x 20 c 5 filter checked all electrical components for broken and loose connections checked amperage on fan motor check the voltage on his strips everything is running normal at this time Furnace in the basement: changed 16 x 25 x 5 filter cleaned off flame sensor checked all electrical components for broken or loose connections checked capacitor checked amperage for fan motor everything is running normal at this time
Completed 2 system ccm maintenance on 2 gas furnaces in attic did not change filters customer already had, i checked both thermostat operations, inspected gas and exhaust, i pulled And cleaned flame sensors , cleared pressure tubes, i checked capacitor mfd as well as the overall cleanliness of both cabinets and blower both systems were very clean, I watched units cycle getting inducer amps and blower amps, I checked ductwork in attic as well, systems were only 4 years old, everything in good working order at the time. Signature collected amps pics uploaded to ST.
Main level zoned system, main limit switch open codes and blower fault motor cannot run codes caused by overheating of furnace. Made adjustments to furnace gas valve and supply air dampers to reduce bypass. Too much bypass of hot air is shutting down system. Also Performed maintenance inspection of systems.
Performed maintenance on 2 furnaces change to filters both 16 x 25 x 5 finger off both flame sensors checked all electrical components for loose or broken connections checked capacitors checked amperage on fan motor checked condition of full pipes and everything is operating normal at this time
Performed maintenance on three furnaces changed 16 x 25 by one filters cleaned off all flame sensors checked all electrical components for any loose or damaged connections Checked all Capacitors and checked amperage on all fan motors everything is running normal at this time
Found leak behind siding at outdoor unit. Removed a piece of siding, cut out bad spot in low pressure refrigerant line, soldered new piece of copper back in refrigerant line, pressure tested system, vacuumed system and charged with r410a refrigerant. Installed piece of siding back. System is charged and operating properly.
Mixed by-pass air with return air. Installed all new Econet thermostats
Need to return and replace EcoNet Tstats with new software. 1- Master and 2- slave. - Mix 10" bypass run on right side of furnace with the 10" return that is coming from main floor. - 1- 12x10x10 Wye 1- 12" collar 15'- 12" R6
Performed maintenance on single system. Replaced both customer provided filters. Treated condensate drain line. Inspected zoning and damper operations. Cleaned flame sensor and inspected furnace operations, electrical connections and components.<br> Estimate for possible addition of air vents will be provided by office or possibly a comfort specialist.<br>