I performed a maintenance on a single heat pump air handler unit I put in a 18x20x1 filter I checked all electrical components and checked the temp rise and checked and cleaned the coils and checked the Freon levels and checked the capacitor everything is in good working order at this time I do recommend replacing the unit at some point dew to the age of the unit and it is an R22 and they don’t make those any more.
Completed one ccm maintenance on furnace located in attic changed 1 16x25x1 filter cleared pressure tube I cleaned flame sensor I inspected gas and exhaust to ensure they were in good order and safe to operate I checked exhaust fan and blower motor amps to make sure they were within specifications. Informed customer of rusted pan underneath evap coil. I fired unit up and watched run brought whole home up to temp.
Install new txv for e ton air handler (part warranty only)
Performed inspection and found a bad TXV on the indoor air handler, checked refrigerant levels and they were at 475/50. Checked full system operations and the indoor fan and outdoor fan was running high on amps but most likely fine.told customer to keep an eye on it.
Residential service call completed in Riverdale Ga
Residential Service Call completed in Riverdale Ga
Residential Quote completed in Riverdale Ga
No power to thermostat, drain line clogged, emergency float switch SS1 shut down system to prevent water overflowing. Cleared drain line and inspected system operations. System is cooling properly.
Service Maintenance/Tune Up completed in Riverdale Ga
I performed a cooling maintenance on a single heat pump air handler I checked all electrical components and replaced the 18x20x1 filter I cleaned and fixed the drain line and i sucked out 7gal of water in the return and I checked the Freon levels and checked the capacitor everything is in good working order at this time.