Powder SpringsGA30127 33.925-84.7
Timely, knowledgeable, and professional technician
Powder SpringsGA30127 33.93-84.6875Powder SpringsGA30127 33.87-84.6875
The service I received was great. I got a quote on the service I needed and the service person arrived on time and was efficient in checking for problems.
Powder SpringsGA30127 33.86-84.6925Came on time and although it was a cool day, did a thorough job at finding what the issue is. Very professional and clean!
Powder SpringsGA30127 33.885-84.695The technician was kind, thoughtful, and thorough. He explained everything well and did not push extra services, except to mention and explain other options. He arrived on time. It was easy to schedule an appointment with their office that was convenient with me. I would highly recommend Comfort Solutions.
Powder SpringsGA30127 33.895-84.6675Dennis came by to diagnose an issue with our unit. He was courteous, knowledgeable and the pricing was fair.
Powder SpringsGA30127 33.895-84.6675Powder SpringsGA30127 33.955-84.7
Tech was on time fir appointment and very polite. Will use again
Powder SpringsGA30127 33.8675-84.6775Completed one ccm maintenance on gas furnace in garage changed 1 16x20x1 filter inspected gas and exhaust pulled and cleaned flame sensor cleared pressure tube, inspected capacitor mfd. i inspected overall cleanliness of system and blower wheel. It is very dirty due to its age, and had slight rust . I watched unit cycle upon start up inducer motor was very very loud, amps still were in range but the sound was not good. I checked blower amps as well all within range. Brought my findings to homeowners attention made her aware of its age and gave solutions and mentioned benefits of replacing system. She agreed, wants to get a quote if front office could send comfort advisor Pics in ST.
I performed a heating maintenance on a single gas Ac unit I replaced the 20x20x1 filter in the hallway I checked all electrical components the temp rise and checked the heat exchangers and checked the gas pressures and checked the flame sensor everything is in good working order at this time.
Customer is on our monthly plan. Performed a heating maintenance on two systems. Main floor and upstairs zoned furnace - I cleared and treated drain line. Cleaned the flame sensor, capacitor is in range at 9.3mf, blower and draft inducing motor amps are also in range. Zone system is operating properly. Replaced both 16x25x1 filters. Downstairs HP/AH system - cleared and treated drain, checked auxiliary heating, amps are in range as well as the blower motor amp. Replaced the 16x20x1 filter. Refrigerant levels are perfect and defrost mode is good. Both systems heating mode are operating properly at this time
I changed the filters out on the upstairs and the downstairs gas furnace made sure that the compartment was cleaned out. They did not have any sheet rock or any thing else inside of them. I also changed the cap on the side of the house with the one that was in the garage.
I performed a one system maintenance on the heat pump, I looked over the indoor unit checked all the wiring low-voltage also looked at the blower motor. I went outside and looked over the outdoor unit checked capacitor and the low voltage on the system I also checked the charge. Did not need to change filter at this time will need to change in cooling season. System is running and heating the house like it supposed to
Completed 3 system ccm maintenance on 2 gas furnaces and one air handler heat pump i inspected thermostat operations gas and exhaust i did change 2 16x25x1 filters they were good I pulled and cleaned flame sensors cleared pressure tubes inspected low voltage wiring, inspected overall cleanliness of furnace and blower, checked capacitor mfd watched furnace run got inducer and blower amps as well. For air handler I turned to emergency heat checked amps and blower amps, i did not change 16x20x1 filter it was good as well, i inspected the cleanliness of both cabinets blower and coil, outside I checked Freon in heating, checked fan motor amps and capacitor mfd all 3 systems are under 5 years old and Performing normally at this time.
Main level furnace control board is intermittently failing. At times ignition sequence is normal and furnace will light and operate however other times just before the gas valve is to get voltage the board stops operations and restarts from beginning of the ignition process. Accurate estimate for furnace control board replacement will be provided Monday. Our office will reach out to customer with estimate and schedule repair depending on part availability.
Warranty- replaced T6 thermostat for a simple T4 thermostat and showed customer how to use it. I also checked system operations and unit is working properly. 20x20x5. Pics uploaded<br> <br> She is aware about memberships
Outdoor unit low on refrigerant. Checked for refrigerant leaks with electronic leak detector, found leak in condenser coil. Sent estimates for new cooling system. Will need to price condenser coil replacement.
Charged the system up and system is cooling working like it should be I put 6 ponds