Christian did a great job and price was more than fair.
LilburnGA30047 33.8775-84.1152016 Trane gas package system overheating because of a extremely dirty 16x25x1 filter. I changed filter and reset unit. Trane system is now working properly. Made customer aware to change filter every 3 months or less. Pics uploaded
Performed 1 system package tuneup. Replaced 1-16x25x1 filter, clean evaporator coil. System clean and operating properly.
Performed 1 furnace tuneup and replaced 1-16x25x1 filter. Hose for pressure switch needs to be replaced in order for furnace to operate properly. Customer will get hose and replace hose himself.
Performed inspection on furnace inside crawlspace, treated condensate pump and change 16 x 25 x 1 filter, checked blower motor amps and capacitor, check temperature rise, performed inspection on outdoor condensing unit, checked refrigerant levels in all electrical components, performed condenser wash, system is operating to specifications at this time.
Performed inspection on furnace inside basement, treated condensate pump and did not change filter at this time, checked blower motor amps, perform inspection on outdoor condensing unit, checked refrigerant levels and all electrical components, the system is clean and operating normally at this time
Warranty parts and labor. Installed new condenser fan motor. After installation tested system operations and system is functioning properly at this time.
Residential Service Call completed in Lilburn Ga
Unit has bad fan motor. Ordering from apex. Po#s-karingriffen-12
Residential Service Call completed in Lilburn Ga
During today’s visit, found outdoor unit for the upstairs system not functioning at all. The circuit breaker was tripped. The capacitor for the outdoor unit was measuring well below specifications. Replaced the capacitor with customer authorization and reset the circuit breaker. The system functions normally after replacing the capacitor and resetting the circuit breaker.