Great experience. In dealing with John
KennesawGA30144 34.0375-84.6625I am very satisfied with the service I received from Comfort Solutions tech Chris. He was friendly, professional, and through.
KennesawGA30152 33.9825-84.7075Tech left sump pump unplugged, no A/C after a few days. Had to figure that out myself. This after spring maintenance and over $400 fan motor replacement this week!
KennesawGA30152 33.97-84.7
Response from Comfort Solutions:
We sincerely apologize about this. The tech had unplugged the sump pump to charge his battery and made the error of forgetting to plug it back in. This was a case of human error. Please call us if you have any issues. We will come back and rectify the situation no matter the time. We strive to ensure our customer's are completely satisfied and happy with our services and we do apologize for this issue.
The technician (Dennis, You Rock!) that arrived was knowledgeable, courteous, and helpful. I would recommend Comfort Solutions to anyone.
KennesawGA30144 34.0575-84.5425KennesawGA30144 34.04-84.6275
KennesawGA30144 34.0375-84.63
I found Comfort Solutions through a family recommendation. They are absolutely amazing from the first call into the office to the job completion. We were with a big name company, that you hear on the radio, but after a couple of expensive recommendations and finding out things that Comfort Solutions includes on their yearly maintenance plan, that the big company wanted extra for, we are 'firing' the big company and switching to comfort Solutions. They truly have been a blessing and it is always a pleasure doing business with them.
KennesawGA30152 33.9825-84.7Installed 6” supply vent for new office area. Customer also wants to add a return in room as well. Estimate in ST. Will need to put boot rails on for supply vent.
Performed 1 gas furnace maintenance. Left customer with new 16x25x1 filter. Furnace clean and operating properly
I performed a heating maintenance on three units two air gas furnaces Ac units and one is a heat pump air handler I replaced two 14x25x1 filters and one 16x20x5 filter I checked all electrical components and checked the temp rises on both gas furnaces and I checked heat exchangers and checked the gas pressures and checked and cleaned the flame sensors and the heat pump air handler I checked all electrical components and checked the temp rise and checked the Freon levels and checked the capacitor everything is in good working order at this time.
I performed a heat maintenance on two gas furnaces I did not replace the 16x25x5 filters homeowner has replaced them recently I cleaned and checked the heat sensor and checked the heat exchangers and checked the gas pressures and temp rise and all electrical components on both units everything is in good working order at this time
I performed a heat maintenance on a single gas furnace i replaced the 16x25x1 filter I cleaned and checked the heat sensor and checked the heat exchangers and checked the gas pressures and temp rise and all electrical components.
I performed a heating maintenance on three gas furnaces Ac units I replaced two 16x25x5 filters and one 14x25x1 filter i checked all electrical components on all units and checked the temp rises and checked the heat exchangers I found on the upstairs unit that the hot surface igniter was broken off i replaced the igniter and the unit is heating normally I checked and cleaned the flame sensors and I the gas pressures on all units everything is in good working order at this time.
Installed new draft inducer assembly for old Lennox gas package unit
Performed maintenance on two furnaces and one air handler Two furnaces in the attic changed 2 16 x 25 by one filters cleaned off both ring sensors checked all electrical components for a broken or loose connections checked capacitors checked amperage on both fan motors everything is running normal at this time Air handler in the basement changed 24 x 30 by one filter checked all electrical components for broken or loose connections checked capacitor checked amperage on fan motor check voltage on heat strips everything is running normal at this time
Performed maintenance on two systems Performed maintenance on furnace in attic checked filters they were still clean homeowner said he just replace them cleaned off flame sensor checked all electrical components for broken or loose connections checked capacitor checked amperage on fan motor this unit is running normal at this time Performed maintenance on air handler in basement 5 inch media filter will still good checked all electrical components for broken or loose connections checked amperage on fan motor checked voltage on heat strips everything is working normal at this time
Performed maintenance on three furnaces and One mini split Furnace upstairs in the attic changed out 16 x 25 by one filter cleaned off flame sensor checked all electrical components for loose or broken connections checked amperage on fan motor checked capacitors performed a small exhaust leak repair everything is running normal at this time Mini split in addition washed washable filters everything seem to be running normal at this time for it Two furnaces in the basement Changed at one 16 x 25 by one filter changed one 14 x 25 by one filter Cleaned off both flame sensors Turn all electrical components on both units for broke or loose connections checked amperage on fan motor checked capacitors everything is running normal at this time