Will use again
JonesboroGA30238 33.4925-84.4125Performed maintenance on furnace inside closet hallway changed 16 x 25 by one filter cleaned off flame sensor checked all electrical components for broken or loose connections checked capacitor checked amperage for fan motor everything is running normal at this time
Replaced shorted shutoff switch for 1987 tempstar furnace and system is now working properly. Previous switch was a combo also for the condensation pump and I only had a single switch. I made customer aware not to run the AC until he runs a extension cord or have us return to install a combo switch before summer. Pics uploaded, 20x25x1 He is also interested in seeing a salesman
Went to no heat said it would run for a little then pop the fuse, I performed short test determined short was coming from a bad contactor got front office to contact management building to inform them of the problem. Unplugged and clipped wire and fuse did not blow again.
The compaster was bad and not allowing the fan to come on. Changed the compaster the fan came on and the system is running and operating like it should be Maine floor
Residential Service Call completed in Jonesboro Ga
Upstairs system has relatively new Goodman gas furnace. With older R22 Ac/outdoor unit and evaporator coil. The furnace was not wired properly resulting in low air speed. Today technician relocated the Y1 wires from thermostat and outdoor unit to proper location on furnace control board. Furnace now operates blower at proper speed for cooling. Outdoor unit at this time is operating normally and refrigerant level is OK system is cooling.
Maintenance/Tune Up completed in Jonesboro Ga
I performed a cooling maintenance on a single gas furnace Ac unit I replaced the 16x25x1 filter I checked all electrical components and checked the temp drop and cleaned the drain line and I checked the Freon levels and checked the capacitor everything is in good working order at this time.
Residential service call completed in Jonesboro Ga
Checked all operations and system operating normally.