Dennis is very professional and very knowlegable
HiramGA30141 33.895-84.7575Technician was on time, diagnosed the problem and had us up and cooling in no time.
HiramGA30141 33.9075-84.74HiramGA30141 33.8625-84.7775
The out door condenser fan motor is locked up and sent the system in to high pressure lock out will need to replace fan motor.
Found bad, 35x5 capacitor in the outdoor unit for the upstairs system. Installed new capacitor. System is now cooling normally. Downstairs system is operating normally at this time also. Recommend that the customer consider our comfort club membership maintenance program.
Completed single system cooling maintenance. Filter is 16x25x1 and recently replaced. Che all electrical components and cleared drains on indoor unit. Cleaned coil,,checked charge and checked all electrical components for the indoor units. System is currently cooling at manufacturers specifications.
This system serves the server room in suite 101
Could not locate correct breaker. Will have to order it. I have a call in to an electrician.
The system was low 3 ponds of 407 wanted to top it off to get it threw the rest of the summer
Upon arrival, checked main floor system and furnace was operating but after checking refrigerant levels, found system to be out of refrigerant. Will be emailing estimate for replacement. Upstairs furnace blower was not coming on, checked capacitor and 5 mfd capacitor was reading 0. Installed new 5 mfd single purpose capacitor for upstairs blower and checked refrigerant levels and system is operating properly
Diagnosed low voltage hard shorts and broken conductor on the outdoor unit wire. Maintenance manager gave approximately for repairs. I replaced the accessible length of low voltage wire for the outdoor unit. I replaced the low voltage fuse and tested system operation. System is operating correctly by the thermostat at this time.
Upstairs 2019 Rheem heat pump low on refrigerant. Customer approved the BETTER option with adding refrigerant and preforming a electronic leak search to pinpoint leak. I added 4.5lbs of refrigerant and found leak at condenser coil in heat pump. Part is still under manufacture warranty so labor would only be charged to replace condenser coil plus refrigerant. Customer will be calling us when ready to preform repairs. System is cooling in the meantime. Pics uploaded, 16x20x5 NO WARRANTY ON REFRIGERANT
Warranty parts, and labor. Technician inspected low-voltage wiring throughout system, including furnace and outdoor unit. Also inspected condensate pump, drain and outdoor contactor.. On arrival, thermostat was blank and warm to the touch 27.8 V present between red and common wires. Installed new thermostat plate, and T6 thermostat. System is operating properly at this time.