Easy team to work with...always professional!
I have used this company for years. I have always had top notch service. Dennis is always very nice, personable, and professional. Highly recommend!!
Awesome job and fix in a timely manner
I called and got a tech sent out the same day... Within only a few hours. Dennis was friendly, explained the problem and fixed the unit in minutes.
The young man that fix our problem was so polite and nice. Not many clean cut looking fellar left. He got to the job finished and was on his way. Thanks for having caring people in your field.
I appreciated the call by the service tech telling me he was on his way.
Found upstairs system low on refrigerant. Performed leak search and found leak at solder joint near liquid line condenser king valve. Photos uploaded. Made solder repair, pressure tested equipment, pulled 500 µm vacuum and re-charged system with 410a refrigerant. Upstairs filter size is 16 x 25 x 1. Warranty system is less than one year old no charge. Inspected operation of downstairs system and downstairs system is operating properly at this time. Downstairs filter size is 16 x 25 x 5. I also took a moment to explain how to operate the thermostats to the homeowner.
Found downstairs system outdoor unit fan motor running backwards. Tested capacitor and capacitor producing 0 µF for fan and only 27 µF or compressor capacitor is 35 x 5 capacitor. Recommend capacitor replacement first, possibility fan motor may need replaced as well. After replacing capacitor fan motor did run the proper direction. Refrigerant level is slightly low however customer states that he only operates the system when he is home and would like to leave it as is for the time being. Should system require further repairs in near future replacement would be recommended
Maintenance/tune up completed in Dallas Ga
I performed a cooling maintenance on a single gas furnace Ac unit I replaced the 14x25x1 filter I checked all electrical components and checked the temp drop and cleaned the drain line and I checked the Freon levels and checked the capacitor everything is in good working order at this time.
3.5ton AC and COIL
P&L- Main level indoor coil is leaking. I will be ordering from apex lithia Customer will be gone for 2 months so I will be ordering coil and when she returns we’ll be ready to swap coil.
Quote for new system in Dallas Ga
Replaced condenser motor system is now operating properly at this time.
Installed new system in Dallas Ga
Drain was clogged which was allowing water to drain in crawl space. Fixed drain so it no longer drains in crawl space and blew out the drain.