Technician was prompt, knowledgeable, courteous, and expeditious. Got the problem resolved quickly.
AcworthGA30101 34.01-84.7025AcworthGA30101 33.98-84.7175
AcworthGA30101 33.9975-84.73
Quick response to service request and technician (Justin) arrived as promised.
AcworthGA30101 33.9975-84.73Performed inspection and maintenance on one basement furnace and one outdoor condenser unit. Cleaned flame sensor, clean pressure switch to and orifice, checked blower motor amperage and capacitor. Treated drain line and condensation pump and changed to 16 x 25 x 1 filters
Summary: 2 system CCM Main-Checked heating operations of system. Replaced filter, checked capacitor outputs and amp drawls, triggered safety switches, cleaned flame sensor, cleaned burners, and cleared drain line. system is operating properly at this time. I checked the Basement system Replaced filter, checked capacitor outputs and amp drawls, checked refrigerant levels and auxiliary heat, triggered safety switches and defrost mode, and cleared drain line. System is operating properly at this time. 20x25x1
Finish basement trim put on missing grills one 10 x 4 supply three 10 x 6 supplies and two 14 x 8 returns also moved flex over from main floor unit to basement unit that was returning air from the gym everything is all complete
The heat strips were not connected into the board inside the air handler therefore the system did not come on because there was no high voltage. I also marked the size of the heat kit on the door of the air handler. The system is running and heating like it supposed to.
New thermostat customer installed says wasn’t working correctly upon further inspection found the thermostat wiring did not match the furnace wiring rewired furnace and thermostat and helped set up Wi-Fi everything is running normal at this time
Performed maintenance on two furnaces Changed 16 x 25 by one filter on both units cleaned off flame sensor checked all electrical components for loose or broken connections checked both capacitors checked amperage on fan motor for both furnaces everything is running normal at this time
Upstairs system operating normally. However Kyle had informed homeowner that pump could be removed and drain ran to the plumbing vent pipe in the attic. So technician removed condensate pump and routed PVC to the plumbing vent pipe in the attic. Photos are uploaded.
Basement Finish
Completed 3 system ccm on three trane furnaces i checked gas and exhaust and thermostat operations i changed all 3 16x25x1 filters, i pulled and cleaned flame sensors i cleared pressure tubes I checked capacitor mfd I checked overall cleanliness of all cabinets and blowers as well as burners, watched units cycle got inducer amps and blower amps, watched flames watched systems run they’re all performing normally at this time informed homeowner of age of units is holding out until they break.
I Installed the nest thermostat for basement system put up two ceiling grills and a 10 x 4 ceiling grill. They were painting in the bedroom in the bathroom and had not painted the walls homeowner said that he would put up the return grills. He also said he would do the bedroom and bathroom. I also moved the supply that runs in io the gym in to the basement system.